Coridea, LLC — Department of Health and Human Services SBIR Phase II: NHLBI
Coridea, LLC — SBIR Phase II award from Department of Health and Human Services.
- Amount
- $997,521
- Agency
- Department of Health and Human Services · National Institutes of Health
- Program / Phase
- SBIR · Phase II
- Topic
- NHLBI
- Solicitation
- PAR14-088
- NAICS
- —
- Place of performance
- NY
- Period
- 2015-04-01 → 2017-03-31
Description
DESCRIPTION provided by applicant The purpose of the proposed work is the development of a nearly painless implantable cardioverter defibrillator ICD Sudden cardiac arrest SCA remains the number one killer in western civilization The underlying mechanism of SCA is usually ventricular fibrillation VF and survival depends on prompt defibrillation Existig defibrillators rely on the delivery of a brief high voltage shock to the heart While this is life saving the shock is extremely painful when delivered to a conscious patient as typically happens when the therapy is provided by an ICD The pain caused by standard ICD shocks is due to the abrupt contraction of skeletal muscles of the chest and abdomen when the shock is applied to the heart Our team has developed a novel means to accomplish painless defibrillation using a burst of ramped high frequency alternating current rHFAC to tetanize skeletal muscle so it does not further contract when a defibrillatory shock is then applied We have already proven substantial reduction in skeletal muscle activation in animals defibrillated using this technology and therefore believe that delivery of this novel therapy by an ICD will be a far less painful alternative to standard defibrillation shocks The goals of the current Direct o Phase II proposal are focused on development of human grade hardware optimization of the therapy proof of efficacy and safety in GLP animal studies and submission of an IDE application to the FDA to enable first in man studies planned for Phase IIb We will design build and test a new system to deliver the novel therapy making sure it meets all electrical and mechanical standards for human use While this system will be an external apparatus it will allow us to prove the value of the novel therapy in animals and humans and therefore pave the way for subsequent development of the technology in a fully implantable device Animal studies will be performed both to determine optimal waveform parameters to reduce skeletal muscle activation and to demonstrate absence of untoward electrical and biological effects using the human grade system Data collected during device testing and animal studies will be submitted in the IDE application Once approved for human use by the FDA we will pursue IRB approval to initiate human investigation in the next phase of the work PUBLIC HEALTH RELEVANCE The goal of the proposed work is the development of a nearly painless implantable cardioverter defibrillator ICD Existing ICDs deliver of a brief high voltag shock to the heart to terminate ventricular fibrillation the arrhythmia that underlies a sudden cardiac arrest The therapy is life saving but extremely painful The novel defibrillation technology pursued in this proposal is based on the use of high frequency alternating current immediately prior to delivery of the high voltage shock The burst of alternating current suppresses the response of skeletal muscle to the shock and thereby eliminates the source of pain The work in this Direct to Phase II application will support an IDE application to the FDA to enable subsequent first in man investigation