ACTUATED MEDICAL, INC. — Department of Health and Human Services SBIR Phase II: 300

ACTUATED MEDICAL, INC. — SBIR Phase II award from Department of Health and Human Services.

Amount
$1,500,000
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase II
Topic
300
Solicitation
PA14-071
NAICS
Place of performance
PA
Period
2016-06-23 → 2018-05-31

Description

DESCRIPTION provided by applicant In this NIH Phase IIB Competing Renewal SBIR project Actuated Medical Inc will finalize and clinically test the andquot Low Insertion Force Epidural LIFE Actuated Needle Insertion System for Enhanced Control and Tactile Feel andquot LIFE uses closed loop control of a vibrating needle to provide the clinician a more controlled entry through tough muscle and tissue while improving tactile feel Epidural anesthesia is a form of regional anesthesia involving injection of drugs directly into the epidural space just outside the spinal cord Epidural anesthesia is used in M births every year in the U S Single shot epidurals routinely given for pain management in the lower back and legs account for another M epidural procedures in the Medicare population alone Epidural procedures require significant clinician expertise for accurate and safe medication delivery due in part to the complexity of anatomy and variety of tissue planes the needle must traverse before reaching the dura The major complication from epidural anesthesia is overshooting the epidural space and puncturing the dural sheath Since epidural procedures are `by feelandapos and human anatomies vary it is difficult for the clinician to anticipate the exact plane in which the tissue resistance will chang The overshoot can occur when the force applied to the needle while traversing from hard tissue density high resistance e g ligamentum flavum into the soft tissue density low resistance e g dura sheath leads to needle acceleration This needle acceleration causes accidental dural punctures in of epidural needle insertions Approximately of dural punctures result in a Post Dural Puncture Headaches PDPH leading to an average increase of hours in the hospital and in of cases an epidural blood patch is given Longer term complications include temporary or permanent cranial nerve injuries subdural hematoma infection inability to perform activities of daily living and missed work PDPH is also the third highest reason for litigation in anesthesiology with an estimated $ M in settlements annually in obstetrics alone The controlled insertion force and velocity through tissue provided by LIFE allows an increased ability to focus on tactile feel resulting in smooth tissue transitions minimizing the complications of PDPH and associated cost in epidural anesthesia Phase IIB Hypothesis LIFE improves procedural safety and effectiveness LIFE procedures result in a clinically significant reduction in complication rate and a clinically significant reduction in onst time of sensory anesthesia Hypotheses to be tested with a Specific Aims Aim Electronic Shut off Development Validated with Safety and Clinical Bench Testing Early Feasibility Clinical Study Aim Design Verification and Validation Testing Aim Pivotal Clinical Trial PUBLIC HEALTH RELEVANCE In this Phase IIB Competing Renewal NIH SBIR Actuated Medical Inc will finalize and clinically test the Low Insertion Force Epidural LIFE Actuated Needle Insertion System for Enhanced Control and Tactile Feel Epidural anesthesia is a form of regional anesthesia involving injection of drugs directly into the epidural space just outside the spinal cord The LIFE system uses closed loop control of a vibrating needle to provide the clinician a more controlled entry through tough muscle and tissue while improving tactile feel for epidural anesthesia reducing the risk of injury to the dural sheath around the spine The need for regional anesthesia is projected to increase due to an aging population obesity and the desire to avoid narcotics particularly in patients with sleep apnea