HEPATOSYS INC — Department of Health and Human Services SBIR Phase I: 300

HEPATOSYS INC — SBIR Phase I award from Department of Health and Human Services.

Amount
$366,141
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase I
Topic
300
Solicitation
PA15-269
NAICS
Place of performance
NC
Period
2016-07-17 → 2018-06-30

Description

DESCRIPTION provided by applicant Liver toxicity is a major barrier to the FDA approval of many new drugs Moreover since the liver is the major site of metabolism of most xenobiotics it is essential to know how the liver metabolizes a potential new drug Because of the many species differences between humans and commonly used animal models testing on human hepatocytes remains the gold standard for drug screening However because the source of these hepatocytes is usually from livers that have been declined for use in transplantation typically because of extended ischemic time the supply of high quality cells is severely limited The long term goal of this project is to reliably improve the availability and viability of primary human hepatocytes isolated from non transplantable Donation after Cardiac Death DCD livers through the modification of a hypothermic machine perfusion HMP resuscitation system that we have developed to restore function to ischemia damaged DCD livers for use in transplantation Human hepatocytes are typically isolated from the pool of non transplantable DCD organs which has been estimated to be as high as of the current donor pool However inconsistent yield and quality of the isolated hepatocytes from these donors has led to limited availability resulting in higher costs for these cells Major factors contributing to this inconsistency are the extended periods of warm ischemia experienced by these organs and the preservation process simple cold storage which does not resuscitate these organs The HepatoSys solution HS coupled with HMP was developed to restore depleted energy stores maintain membrane stability and minimize oxidation damage resulting in a resuscitated liver Our results indicate that our process can be used to successfully isolate high quality hepatocytes from otherwise unusable livers In addition we will add further commercial value to the technology by testing prolonged HMP of livers to provide greater flexibility in making fresh cells available and the ability of additional oxygenated cold storage of hepatocytes in the HS to improve the quality of freshly isolated and cryopreserved hepatocytes To achieve these goals we propose the following aims Specific Aim Test the efficacy of prolonged HMP of livers with the HepatoSys solution on yield viability plateability and function of fresh hepatocytes isolated from rat DCD livers Test the effect of up to hours HMP followed by hepatocyte isolation on yield viability plateability and function of freshly plated isolated hepatocytes from DCD rats Specific Aim Test the efficacy of additional oxygenated cold storage CS of fresh hepatocytes after isolation in the HepatoSys solution on yield viability plateability and functio from DCD rat livers Test the ability of additional CS of isolated hepatocytes in the HS from DCD rats to maintain or improve the viability plateability of freshly isolated rat hepatocytes Specifc Aim Test the efficacy of optimized conditions identified in aims and on yield viability plateability and function of freshly isolated hepatocytes from a small group of human DCD livers Completion of these specific aims will provide a proof of concept that this technology has a potentially commercially valuable method to obtain viable plateable and functional hepatocytes from livers currently not usable while providing greater flexibility in making freshly isolated hepatocytes available which will allow TRL and HepatoSys to increase market share A Phase II application will seek to add further commercial value to the technology by expanding the pool to even poorer quality donor livers and improving the quality of cryopreserved hepatocytes PUBLIC HEALTH RELEVANCE The long term goal of this project is to improve the quality and availability of primary human hepatocytes isolated from non transplantable Donation after Cardiac Death DCD livers This is designed to address the very important need for an abundant supply of high quality human hepatocytes for metabolism and toxicity testing in new drug development HepatoSys Inc has developed a hypothermic machine perfusion solution that resuscitates livers with extended periods of warm ischemia similar to those from these DCD livers Our preliminary study demonstrated the ability to extend warm ischemic time up to minutes in rat livers and improve function by incubating isolated cells in HepatoSys Solution prior to culturing In addition we showed that our technology was at least as effective in human DCD livers especially in more damaged livers Based on these exciting preliminary results we will collaborate with our commercialization partner Triangle Research Labs TRL to test whether prolonged HMP with the HS will improve yield viability and function of hepatocytes from DCD livers to an extent that is commercially expedient Additionally this will provide greater flexibility in making freshly isolated cells available through prolonged HMP The collaborations between the liver physiologist and biomedical engineer at HepatoSys Inc along with the strategic partnership with TRL a leading company in providing human hepatocytes should allow us to quickly translate this innovative technology into a commercially viable product at the end of this project