INTUOR TECHNOLOGIES LLC — Department of Health and Human Services SBIR Phase I: N

INTUOR TECHNOLOGIES LLC — SBIR Phase I award from Department of Health and Human Services.

Amount
$174,998
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase I
Topic
N
Solicitation
PA15-269
NAICS
Place of performance
AZ
Period
2016-09-30 → 2017-03-31

Description

DESCRIPTION provided by applicant Intraocular pressure IOP is arguably the second most important criteria used to assess visual acuity when eye care professionals are diagnosing treating and managing patients The patented Intuor Applanation Tonometer IAT prism design is a novel and simple approach for improving the accuracy of IOP measurement in the eye The proposal describes an inexpensive and easily adoptable approach to improving the accuracy of what has been considered the `gold standardandapos of IOP measurement for many decades the Goldmann Applanation Tonometry GAT Experts in the field identified significant errors in patient variability in the GAT IOP measurements for corneal thickness rigidity curvature and tear film The combined error of patient variable parameters is potentially sight threatening to a large population of patients including those with glaucoma or undiagnosed ocular hypertension from other causes However currently this is still the best clinical method available Attempts to develop other IOP correcting tonometers had limited success due to being cumbersome to use and expensive In contrast our approach Intuor Applanation Tonometry IAT optimizes the shape of the GATandapos s prism surface without any change in measurement technique or examination time and addresses all known errors in GAT IOP measurements and accomplishes this with minimal expense less than $ Preliminary mathematical modeling of the IAT indicates at least reduction in each error parameter when compared to the GAT significantly improving the fidelity of IOP measurement Intuorandapos s novel technology will support the NIH NEI mission by improving human health and function through maximizing the care providerandapos s ability to more accurately measure the patientandapos s IOP guiding both individual patient diagnosis and treatment as well as improved global evaluation of disease processes and treatment modalities The IAT will also reduce healthcare costs through more timely diagnosis and accurate treatment Intuor Technologies would utilize a Phase I award to accomplish three specific aims utilize an existing opto mechanical mathematical model to optimize the design of our IAT build and verify a working ex vivo optimized prototype to demonstrate substantial equivalence of the IAT prism to the GAT prism for medical device FDA k submission and demonstrate the optimized IAT prototype in vivo comparing it to the GAT using a true intracameral IOP Most importantly after achieving these aims Intuor Technologies will be able to proceed directly to commercialization and marketing PUBLIC HEALTH RELEVANCE Intuor Technologiesandapos Applanation Tonometry IAT optimizes the shape of the Goldman Applanation Tonometerandapos s GAT prism surface to address all known GAT intraocular eye pressure errors without changing clinical practice or procedure time and at minimal expense less than $