Description
Gout affects millions of people in the US and the economic burden due to the disease is comparable to other chronic conditions such as Parkinsonandapos s disease or migraine Accurate identification of crystal identity is essential to pursue an appropriate form of treatment Patients who have gout attacks seek care at hospitals outpatient centers urgent care or the ER with hot swollen and painful joints therefore gout symptoms can be confused with other forms of arthritis Conclusive diagnosis requires observation of synovial aspirates by polarized light microscopy PLM to confirm the presence of negatively or positively birefringent crystals In practice PLM analysis as a billable service requires a microscope equipped with compensated polarization optics and a Clinical Laboratory Improvement Amendments CLIA for the laboratory Certification by pathologists or rheumatologists is done by professional organizations followed by credentialing and the hospital or lab that performs the analysis and subject to hospital policy about who may report PLM findings For all intensive purposes PLM is therefore only feasible in major healthcare centers and central laboratories in selected rheumatology practices Therefore clinicians on the front line may be unable to diagnose gout during their clinical encounter or they depend on presumptive diagnosis based on clinical symptoms that lack sensitivity and specificity The new American College of Rheumatology gout classification criteria are an attempt to address this problem but truly a facile and automated point of care testing for gout and pseudogout is needed in primary care settings to inform the diagnosis and treatment of these diseases Point of care Raman device POCR is an existing prototype that is developed at Case Western Reserve University CWRU with past NIH R and R to identify MSU and CPPD crystals in synovial fluid The method involves a simple and facile sample preparation to isolate crystals in a disposable cartridge that is then inserted in a compact cost efficient and automated device which identifies the crystal species based on fingerprint molecular spectroscopy By design the method should be able to be performed by the non specialist with minimal training POCR was evaluated using synovial fluid samples from symptomatic patients N and there was more than agreement between the diagnoses of POCR and PLM conducted by a certified technician pathologist During a prior R Akkus Singer clinical synovial sample analyses were performed by researchers The current version of the device needs a moderate number of modifications and customization to ready it for use by clinicians This Phase I SBIR will demonstrate that diagnosis of gout pseudogout by POCR as executed by the non specialist staff at point of service will agree with the diagnosis by PLM conducted by certified operators During first aim the prototype developed in CWRU will be transferred to Spectral Energies LLC who will refine it to make a clinically executable prototype The clinical prototype will be used and evaluated by clinical staff in the second aim The diagnostic outcome of synovial fluid analysis on freshly collected samples by POCR in the hands of non expert clinical staff will be compared to PLM analysis performed as standard of care The Phase I study will provide us with a clinically applicable POCR and pave the way for a multi site clinical assessment of the device in a follow up Phase II study that aims to demonstrate that POCR enables the diagnosis of gout in settings which are not equipped with PLM and CLIA certified laboratories and accredited operators Conclusive diagnosis of gout mandates identification of crystals in joint fluid microscopically by a certified operator who is not available in many healthcare settings Therefore gout is underdiagnosed or misdiagnosed often The project will develop a point of care device for facile and automated identification of gout in the clinic