MAGNETIC INSIGHT, INC — Department of Health and Human Services SBIR Phase I: NIDA
MAGNETIC INSIGHT, INC — SBIR Phase I award from Department of Health and Human Services.
- Amount
- $223,825
- Agency
- Department of Health and Human Services · National Institutes of Health
- Program / Phase
- SBIR · Phase I
- Topic
- NIDA
- Solicitation
- PA14-071
- NAICS
- —
- Place of performance
- CA
- Period
- 2015-09-15 → 2016-08-31
Description
DESCRIPTION provided by applicant There is a clinical need for new neurovascular imaging techniques for the diagnosis staging and monitoring of acute stroke and sub acute stenoses arterial venous malformations AVMs and aneurysms among others Together these etiologies frequently manifest in acute stroke and kill over people per year with an estimated cost the US healthcare system of over billion dollars per year A reliable and non invasive neurovascular stress test similar in concept to a cardiac stress test would revolutionize cerebrovascular imaging and stroke prevention It is well known that perfusion imaging combined with a means of altering cerebral perfusion pressure or cerebrovascular resistance can measure a patientandapos s cerebrovascular reserve and predict the risk of stroke Current neurovascular imaging techniques suffer from limitations in radiation exposure safety speed sensitivity and specificity that prevent their use in measuring cerebrovascular reserve Magnetic particle imaging MPI is a new imaging technology that answers a clinical need for a safe rapid D perfusion and D angiography technique without ionizing radiation or toxic tracers to image intracranial diseases such as stenosis stroke aneurysm vasospasms and malformations The MPI tracer is made with Iron Oxide SPIO significantly safer than Iodine used in CT and fluoroscopy and Gadolinum used in MRI The safe tracer and absence of harmful radiation leads to reduced long term medical costs for patient undergoing diagnostic angiography and especially patients undergoing repeated diagnostic angiography procedures associated with long term care MPI produces absolutely no signal from overlying tissues creating a positive contrast and quantitative angiography images or real time perfusion with unprecedented contrast to noise and signal to noise Successful completion of a human brain imager will mark the beginning of a new field of diagnostic imaging comparable in scope to the introduction of MRI CT or Ultrasound This project aims to develop the first high resolution real time MPI system tailored for clinical cerebrovascular imaging The proposed system will be the worldandapos s highest sensitivity and highest resolution tomographic MPI scanner In Phase I of this SBIR we will complete the main magnet design build a scale prototype and develop our manufacturing plan In Phase II we will construct the magnet and obtain phantom and animal images In Phase III we will perform animal and then human testing PUBLIC HEALTH RELEVANCE Magnetic Particle Imaging MPI is a new imaging modality whose unique contrast safety and speed solves several limitations and concerns of current neurovascular imaging protocols Mutagenic radiation kidney disease and brain damage has caused major concern and re evaluation on the use of CT angiography and MR angiography methods Here we propose to commercialize the first cerebrovascular MPI imager offering an alternative and new modality to allow safe assessment staging and monitoring of neurovascular diseases such as stroke aneurism and other vaso malformations Successful completion of a human brain MPI imager will mark the beginning of a new field of diagnostic imaging comparable in scope to the introduction of MRI CT or Ultrasound