Simplex Scientific — Department of Health and Human Services SBIR Phase I: 300

Simplex Scientific — SBIR Phase I award from Department of Health and Human Services.

Amount
$208,268
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase I
Topic
300
Solicitation
PA14-071
NAICS
Place of performance
WI
Period
2015-03-01 → 2016-02-29

Description

DESCRIPTION provided by applicant Simplex Scientific LLC Simplex is proposing to develop a medical device that can accurately measure hypovolemia due to hemorrhage from trauma which can lead to shock and ultimately death and which will be suitable for deployment at civilian and military trauma sites and during transport where motion induced artifacts interfere with conventional technologies There is an urgent need for a reliable rapid easy to use hypovolemia detector at the trauma site and during medical transport After trauma hemorrhage leads to blood loss and hemorrhagic shock a leading cause for death among the young and healthy especially in combat because their bodies do not manifest overt symptoms until the later stages Stage III which is associated with higher morbidity and mortality Current methods cannot reliably detect early stages of hemorrhagic shock as outward physical symptoms are unreliable and first responders FRs usually EMTs or combat medics often cannot estimate the blood volume lost even with external hemorrhage Approximate indicators of hypovolemia blood pressure and pulse pressure require valid readings which are difficult to obtain when the patient is in motion ambulance or helicopter and require knowing a patientandapos s baseline numbers for accurate diagnosis When a patient has stable vital signs as they often do in Stage I or II hypovolemia diagnosis can often only occur in a hospital Thus a reliable means to ascertain when a victim is in early stage hypovolemia would allow FRs to provide oxygen to victims and move them higher in triage than their overt symptoms might otherwise indicate both of which would enhance outcomes and reduce mortality all while reducing treatment costs In this two Phase project Simplex intends to create a portable device that can reliably and objectively identify when a trauma victim is in early stage hypovolemia regardless of motion or baseline data In order to demonstrate feasibility of this device in Phase I we will attempt to validate our hypothesis which is that there is a measurable reading that is consistent across all patients that can be used to identify when a patient is in early stage hypovolemia To do this in Aim we will study human subjects to obtain baseline measurements and measurements taken under stress using a lower body negative pressure chamber a hypobaric chamber to ascertain whether the measurement identified in preliminary studies is accurate across the target population young and healthy persons Then in Aim we will generate an algorithm to correlate our measurements to early stage hypovolemia In Aim we will create a bread board prototype device that should be able to identify early stage hypovolemia regardless of baseline data In Phase II we will miniaturize this prototype device ruggedize it for field us and test it under field conditions At the conclusion of this two stage process we should have a reliable and objective device capable of identifying early stage hypovolemia in the field PUBLIC HEALTH RELEVANCE Simplex Scientific LLC Simplex is proposing to develop a medical device that can accurately measure hypovolemia due to hemorrhage from trauma which can lead to shock and ultimately death and which will be suitable for deployment at civilian and military trauma sites and during transport where motion induced artifacts interfere with conventional technologies To demonstrate feasibility of our device in Phase I we will attempt to validate that there is a measurable reading consistent across subjects that can be used to identify when a person is in early stage hypovolemia If this hypothesis proves accurate we will create a bread board prototype device to detect and identify early stage hypovolemia regardless of patient baseline data or external movement By allowing early responders to more readily identify early stage hypovolemia our innovative device will save lives and reduce costs related to hemorrhagic shock