Koronis Biomedical Technologies Corp. — Department of Health and Human Services SBIR Phase II: 400

Koronis Biomedical Technologies Corp. — SBIR Phase II award from Department of Health and Human Services.

Phase II SBIR prototype / development signal

  • Phase II is where Department of Health and Human Services funds deeper R&D after feasibility. Incumbents with Phase II history are serious competitors on adjacent topics.
  • Use this award as past-performance context and to map customer organizations for STRATFI/TACFI-style transition planning.
  • At $1,708,661, this is a large obligation for typical SBIR Phase sizing — worth reviewing for scope breadth and teaming opportunity.
  • Topic code 400 links this award to a solicitation family — search the same topic stem for incumbents and recompete timing.

Informational capture context from public federal data — not legal or bid advice.

Amount
$1,708,661
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase II
Topic
400
Solicitation
PA20-262
NAICS
Place of performance
MN
Period
2021-05-18 → 2024-04-30

Description

Abstract Koronis Biomedical Technologies (KBT) proposes to develop and fully evaluate a renal replacement therapy (RRT) machine specifically targeted for critically-ill small children and neonates with acute kidney injury (AKI), fluid overload, and kidney failure. In recent years, continuous renal replacement therapy (CRRT) has emerged as the preferred method for providing kidney support to these patients, especially those who are hemodynamically unstable. Continuous veno-venous hemofiltration (CVVH) is a form of CRRT built on hemofiltration: waste products and fluid in plasma are removed from the blood by a pressure gradient over a filter, while a replacement fluid is infused to maintain fluid balance. Unfortunately, neonates infrequently receive renal replacement therapy due to the technical challenges of traditional CRRT machines that make therapy initiation very difficult, even at experienced tertiary children’s hospitals. Machines designed for adult- sized patients, but commonly used in pediatric care, require large catheters, tubing, and filters. This results in a high extracorporeal volume (ECV, the total volume of blood in the external circuit—the tubing and hemofilter) relative to a small patient’s size, as well as higher blood flows, higher clearance rates, and higher risks. Numerous medical centers do not even offer CRRT to infants, let alone for critically-ill neonates or premature infants, due to the inherent risks. At therapy initiation, a volume of fluid roughly equivalent to the ECV must be injected into the blood circuit to “prime” the pump. For CRRT in larger children and adults, the priming fluid is simply saline. If, however, the amount of fluid required to prime the circuit is greater than 10% of the patient’s total blood volume, the saline fluid could significantly dilute the patient’s blood, leading to hemodynamic instability. To avoid this outcome, a donor “blood prime” is used, though it is not without risks, such as hypocalcemia, acidosis, hyperkalemia, and a loss of platelets and coagulation functions. KBT’s Phase II SBIR project proposes to bring a new CRRT device with a lower ECV to market that is specifically targeted for small children and neonates, eliminating the need for blood primes. The performance and safety of the proposed highly integrated CRRT system will be evaluated in a clinical trial.