AI BIOSCIENCES, INC. — Department of Health and Human Services SBIR Phase I: NIAID

AI BIOSCIENCES, INC. — SBIR Phase I award from Department of Health and Human Services.

Amount
$224,955
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase I
Topic
NIAID
Solicitation
PA15-269
NAICS
Place of performance
TX
Period
2017-01-01 → 2017-12-31

Description

PROJECT SUMMARY The aim of this proposal is to develop a rapid low cost and easy to use POC diagnostic test for Zika virus ZIKV ZIKV is an emerging mosquito borne Flavivirus that has gained global attention due to new evidence that it is linked to birth defect microcephaly Additionally health experts are also concerned about the link between the virus and Guillain Barr syndrome GBS President Obama announced in early February of that he is asking Congress for more than $ billion in emergency funding to expand the United States efforts to combat Zika One of the most vital tools necessary to confront an outbreak like the Zika virus is a reliable accurate and easily accessible diagnostic test The issue with existing tests is that they often fail to distinguish between Zika and similar viruses to which people living in Central and South America are frequently exposed The CDC has recommended the use of molecular detection e g reverse transcription polymerase chain reaction or RT PCR to identify Zika virus in suspected cases While CDC and qualified state health department labs can perform the RT PCR ZIKV test these labs use highly sophisticated instruments and turnaround times are typically weeks To this end we will collaborate with internationally known arboviruses expert and leading US ZIKV researcher Professor Scott Weaver at the University of Texas Medical Branch UTMB to develop a low cost POC system for testing ZIKVs infection in non traditional healthcare settings in the US and Americas This device uses a wind up music box to drive an innovatively designed plastic gear set to automate nucleic acid extraction in pre filled cartridges and to elute the purified RNA directly into real time master mix of amplification assays such as reverse transcription recombinase polymerase amplification reaction RT RPA or polymerase chain reactions RT PCR The gear set and the disposable cartridge can be enclosed for biosafety and contamination prevention This portable system lacks complicated microfluidics pumps or other sensitive high cost components thus making it suitable for resource limited countries The simple sample to answer process requires minimal training and informs healthcare workers of patients diagnostic statuses In Phase I we will first demonstrate quality RNA extraction from spiked serum and urine samples in min using pre filled cartridges and the gear set We will also demonstrate that the eluted RNA samples can be rapidly amplified to confirm the presence of ZIKV RNA using isothermal real time RT RPA assay We aim to complete real time RT RPA amplification reactions in less than min The fluorescent signal produced from amplification will be monitored using LEDs for excitation and a smartphone camera for emission monitoring and analysis Near the end of Phase I our collaborator will validate our device for ZIKV detection The successful development and commercialization of our technology will lead to molecular diagnostics being implemented in non laboratory settings and will assist resource limited populations to get tested for Zika In short our portable system will be pertinent to the ongoing ZIKV global health emergency PROJECT NARRATIVE As the Zika virus continues to spread through the Americas health officials in the United States are rushing to learn more about the virus and prepare for cases Currently the CDC s emergency operations center is on its highest level alert for the Zika response It is critical that the Zika virus test is inexpensive easy to implement by healthcare workers in resource limiting settings and most importantly fast enough that patients can be tested and consulted without needing a return visit Our proposed molecular diagnostics device will be able to be performed by healthcare workers outside of the laboratory and deliver results in around min to meet the needs of patients and healthcare workers in identifying those infected with Zika virus