GLUCOSENTIENT INC — Department of Health and Human Services SBIR Phase I: NICHD

GLUCOSENTIENT INC — SBIR Phase I award from Department of Health and Human Services.

Amount
$223,500
Agency
Department of Health and Human Services · National Institutes of Health
Program / Phase
SBIR · Phase I
Topic
NICHD
Solicitation
PA16-302
NAICS
Place of performance
IL
Period
2017-04-01 → 2019-03-31

Description

Project Summary Abstract Phenylketonuria PKU is a serious inborn metabolic disorder affecting out of every children born in the U S annually Characteristic effect of PKU is the impaired capability of the body to convert the amino acid phenylalanine Phe to tyrosine and as a result Phe level is elevated in the blood stream While Phe is required for normal growth and brain development excess Phe leads brain damage and ultimately severe intellectual impairment The effects of prolonged exposure to Phe is much more pronounced during childhood and pregnancy resulting in growth retardation and neurological impairment in children development delay microcephaly and congenital heart disease in fetuses Therefore patients with PKU need carefully control and monitoring of their blood Phe level for their whole lives especially for infants children and pregnant women To control blood Phe levels a specially designed low Phe diet which is devoid of protein containing food must be followed Since Phe diet are difficult to follow and prolonged exposure to elevated Phe as well as frequent fluctuation of blood Phe impacts normal growth and brain development blood Phe levels are routinely monitored for patients with PKU However monitoring blood Phe today requires long turn around time since blood sample needs to be first collected via a blood drawn or on filter card then analyzed in a clinical laboratory using costly and sophisticated instrument Hence many PKU patients can only maintain a suboptimal blood Phe levels even they are willing to make dietary adjustment Therefore home Phe monitoring providing with immediate test result is imperative to achieve better health outcomes and to avoid neurocognitive issues Although methods have been reported for monitoring Phe at home most of them rely on optical detection that is vulnerable to interferences from colored species in clinical samples or electrochemical detection that uses sophisticated assay methods or highly modified electrochemical detectors limiting their commercial potentials Based on this compelling need and our recent discovery that many commercially available Blood Glucose Meters BGMs can measure levels of NADH a cofactor in many enzymatic assays we propose to repurpose the BGM widely used by diabetics for PKU patients to monitor blood Phe levels We have developed a technology that allows the direct use of existing glucose test strips for quantification of Phe via an enzyme phenylalanine dehydrogenase that generates NADH in the presence of Phe Furthermore we have developed a customized meter to improve the NADH sensitivity while still using existing glucose test strips In this Phase I project we will focus on demonstrating the feasibility by developing a BGM based Phe assay followed by sensor strip development By leveraging today s BGM platform we can drastically reduce the time and cost associated with medical device Randamp D and scale up production while delivering an easy to use and affordable solution for PKU patients to monitor their Phe levels rapidly at home or at any point of care setting Project Narrative This SBIR Phase I proposal aims to take advantage of existing glucose meter technology by employing an innovative approach to develop a home use device for measuring blood levels of phenylalanine which is routinely monitored to ensure patients with phenylketonuria or PKU have properly maintained their blood phenylalanine level Providing PKU patients with an affordable easy to use and rapid monitoring device can significant improve the efficiency and efficacy in managing their symptoms leading to a healthier and more productive life